Laboratory
Experiments > Three Tank System > Technical data
TTS20 Three-Tank-System
The
Three-Tank-System consists of three plexiglass-cylinders
which are serially interconnected by stop valves.
The pumps1 and 2 suck distilled water from
the basin, thus supplying the two cylinders on
the left- and right-hand side of the set-up. The level
of the liquid inside all three cylinders is supervised via process pressure transmitters. The basin and the three
cylinders present a unit manufactured out of plexiglass.
|
|
Dimension
Sizes and
Weight of the System:- Length
: 1280 mm
- Width
: 350 mm
- Height
: 890 mm
- Weight
: 54 kg
|
Pumps:
- Voltage
: +12 V
- Current
consumption : 1.4 A
- Pump
performance : 7 l/min
- Pressure
: 1.4 bar
|
Sensors:
- Range
: 0 ... 100 mbar
- Output
signal : 0 ... 20 mA two-wire.
|
|
Actuator
with signal adaption
The
amplifier, the mains supply unit and a signal adaption unit are contained
inside of a 19’’-box. The box also contains the electrical disturbance unit:
The 3 sensor signals can be disrupted by switches or scaled by potentiometers.
The control signals for the pumps can be scaled via potentiometers.
Mains: (230 V, 50/60 Hz on request 110 V, 50/60 Hz)
Amplifier
inputs :
- Pump
control signals: 0 ... +10 V
Amplifier
outputs :
- Voltages
for the pumps: +12 V (PWM)
Inputs
of the signal adaption unit :
- 3
sensor signals, range: 0 ... 20 mA
- 2
control signals for the pumps in the range: -10 ... +10 V
Outputs
of the signal adaption unit :
- Liquid
levels of cylinders: ±10 V +9 V = 0 cm, -8.61V = 60 cm
- 2
control signals for the pumps in the range: 0 ... +10 V
Technical